Product Details:
|
Lubrication Style: | Lubricated | Voltage: | 380v/3ph/50hz(or Customized) |
---|---|---|---|
Capacity: | 1.5Nm3/min | Specification: | Standard |
Packing Box: | Export Plywood Box | Rated Pressure: | 0.6-1.0MPa |
High Light: | aetok 380v heatless regenerative air dryer,aetok 380v heatless regenerative air dryers,china aetok 380v heatless regenerative air dryers |
Heat Regenerative Adsorption Type Compressed Air Dryer Adsorb Dryer
High-quality adsorbent, stable dew point
* 30% residual filling is anti-aging, which can easily cope with short period of severe working conditions;
* 3.0mm diameter, larger active surface area, high strength, good water resistance
High-reliability design, stable and reliable performance, minimal maintenance
* Excellent simplified design to ensure no less than 5.2 seconds of contact time;
* Layered dense filling process, low risk of adsorbent wear, long life, reliable dew point;
* Adopt well-known valve parts with low risk of leakage, long life and less maintenance
Advanced control and monitoring system
* Adopt PLC or SCM programmable controller
* Brilliant control, powerful parameter recording function can realize accurate control of the whole process;
Inlet Temperature | ≤38℃ |
Adsorbent | Alumina,Molecular Sieving |
Pressure Dew Point | -20~-40℃ |
Regeneration Gas Consumption | ≤13% |
Inlet oil content | ≤0.1ppm |
Working Pressure | 0.6-0.95Mpa |
Control Mode | Microcomputer Automatic Control |
Main tech parameters:
Main specialties
Energy-saving dew point sensor with standard configuration (medium and large series)
All function indicators are displayed.
Small size, light weight, convenient maintenance.
Heatless Adsorption Dryer Workflow
1.Two towers drying in parallel Before start-up, the inlet and outlet valves of the left and right towers are always open, and compressed air passes through both towers to the point of use at the same time. |
|
2. The left tower is dried and the right tower is regenerated After the power is turned on, the right tower inlet / outlet valve is closed, the right tower regeneration inlet / exhaust valve is opened, and the compressed air flows through the left tower to be dried. The dry air passes through the orifice plate, and the right tower is regenerated after being throttled and expanded.At this time, the pressure of the right tower should be 0 kg. The compressed air containing moisture is released into the atmosphere through the right tower regeneration exhaust valve and muffler. left and right towers are always open, and compressed air passes through the two towers to the point of use simultaneously. |
|
3.Regeneration is over, ready to boost After 4 and a half minutes of regeneration, the right tower regeneration exhaust valve was closed, and the right tower began to boost pressure. |
|
4. The left tower is dry and the right tower is boosted The booster valve opens, and the pressure of the two towers slowly rises to equilibrium.After 5 minutes, the tower is changed to enter the next cycle. |
Contact Person: Mr. Leo