7-91kw Precision Air Conditioning For Data Center 10000m3/H Precision Aircond

I'm Online Chat Now

7-91kw Precision Air Conditioning For Data Center 10000m3/H Precision Aircond

7-91kw Precision Air Conditioning For Data Center 10000m3/H Precision Aircond
7-91kw Precision Air Conditioning For Data Center 10000m3/H Precision Aircond

Large Image :  7-91kw Precision Air Conditioning For Data Center 10000m3/H Precision Aircond

Product Details:
Place of Origin: JAPAN
Brand Name: AETOK
Certification: SGS,CE
Model Number: PAP
Payment & Shipping Terms:
Minimum Order Quantity: 1 set
Price: Negotiate
Packaging Details: Normal exported wooden case
Delivery Time: 5-8 work days
Payment Terms: L/C, T/T, Western Union, MoneyGram
Supply Ability: 1000 sets/per year

7-91kw Precision Air Conditioning For Data Center 10000m3/H Precision Aircond

Description
Operating Voltage: 380VAC, 380/400 VAC Airflow: 10000m³/h
Temperature And Humidity Control Precision: ±0.1, ±1.0 Cooling / Heating Output (50 / 60Hz): 1.8 / 2.12
(Maximum Cooling Output): (1.2 / 1.42) Mounting: Floor Standing
Supply Power: Single Phase 100V ± 10% (50 / 60);Three-phase 200 ± 10 % (50/60)
High Light:

7kw precision air conditioning for data center

,

91kw precision air conditioning for data center

,

10000m3 h precision aircond

Precision Control Air Conditioner 7-91kW Capacity Systems For Technological Room Applications

 

Thermoelectric air conditioner operate by the Peltier effect(which also goes by the more general name thermoelectric effect).The device has two sides,and when DC current flows through the device,it brings heat from one side to the other,so that one side gets cooler while the other gets hotter.The ' hot' side is attached to a heat sink so that it remains at ambient temperature,while the cool side goes below room temperature.In some applictions,multiple coolers can be cascaded together for lower temperature.

 

 

Proudct Feature

1 Using semiconductor electronic cooling, small volume, light weight.

2 No compressor, no Freon, no pollution, no vibration, no leak.

3 Using no pollution material, compliance CE.

4 Free mounting, applicable to a variety of places.

5 Working ambient temperature: -10C~+50℃.

6 Dense fin extrusion heat sink, high efficiency.

7 High-dense foam insulation between heat sink and cooled heat sink.
8 Hot-side heat sink overheat protection temperature setting +75℃± 5℃.
9 Applied in sealing, vibration or rotation places such as compressors do not work.

 

Applicable Industries
Air Conditioner For Server Room
Condition
New
Type
EVAPORATIVE AIR COOLER
Operating Voltage
380/400 VAC, Optional, 380V/3Ph/50Hz & Others
Mounting
Floor Standing
Warranty
1 Year
Dimension(L*W*H)
750*650*1975/custom made
Key Selling Points
R410a
Airflow
2000m³/h
Machinery Test Report
Provided
Video outgoing-inspection
Provided
Warranty of core components
1 Year
Core Components
PLC, pressure vessel
Weight (KG)
230KG
Dimensions
Customized
Condenser
Air cooled aluminum fin copper tube air heat exchanger
Compressor
Scroll compressor
Standard condenser
DMC17WT3
Total cooling capacity
17
Sensible cooling capacity
15.5
Air volume (m3/h)
4300
Heating capacity (kW)
5.5
FLA (A)
12

 

1.1 All equipment's provided under this specification shall be commercially in operation which is field proven for at least five years within three or more countries outside the manufacturer country.
1.2 AHU materials shall be avoided from any part of the equipment.
1.3 Equipment size and weight shall be the minimum possible.
1.4 Construction of all equipment and quality of components shall be in accordance with the best current standards of air conditioning for strength, reliability, durability, and safety.
1.5 Parts requiring dust proofing, such as relays and contactors shall be protected with dust proof covers.
1.6 Wiring in each equipment shall be systematically color-coded and neatly wired.
1.7 All air conditioning equipment shall operate on 220V± 10%, single phase and a frequency of 50Hz±5%.
1.8 The system should restart automatically, when power turn on, after mains power failure.
1.9 The units (evaporator and condenser) shall be separable suitable for the installation of the condensing units out-door and the cooling unit indoor.

 