Product Details:
|
Operating Voltage: | 220/380/400 VAC | Controller: | PLC Intelligent Touch Screen |
---|---|---|---|
Airflow: | 30000m3/h | Cooling / Heating Output (50 / 60Hz): | 1.8 / 2.12 |
(Maximum Cooling Output): | (1.2 / 1.42) | Key Selling Points: | Low Noise Level |
Supply Power: | Single Phase 100V ± 10% (50 / 60);Three-phase 200 ± 10 % (50/60) | ||
High Light: | PLC Precision Air Conditioner,220vac Precision Air Conditioner,220w precision air conditioning system for data center |
Small Medium Computer Room Air Cooled Precision Air Conditioner
Energy-efficient
▪ Large air volume, small enthalpy difference and high sensible heat ratio meet the requirements of the computer room environment, providing a stable temperature and humidity environment for the computer room
▪ Energy-efficient compressors and fans are matched with the precise throttling design of the expansion valve to maximize energy efficiency.
▪ The outdoor fan adopts stepless speed regulation control to match the system's condensing pressure operation to reduce the
energy consumption of the whole machine.
▪ The control system has a group control function, centralized control of multiple devices, and realizes the overall energy saving
of the refrigeration equipment in the computer room.
Stable and reliable
▪ System design is stable and reliable.
▪ The complete alarm protection function system realizes multi-level alarm protection such as power supply protection, water leakage protection, temperature and humidity exceeding limit, and system device protection.
▪ Stable operation with ultra-wide voltage input, with power protection functions such as phase sequence detection.
▪ Smart self- start function after power recovery.
Smart Control
▪ The 4.3-inch color touch screen displays the system function status and component operation status in real time.
▪ The control system has multi-level password protection, intelligently judges and distinguishes different levels of alarm information.
▪ Equipped with group control functions such as rotation and backup to realize the automatic switching operation of the main machine and the standby machine at the set time.
▪ Using standard RS485 monitoring interface, standard RS485 protocol can be provided free of charge.
▪ It can realize remote setting and monitoring of unit operating status and alarm information.
Condition
|
New
|
Mounting
|
Floor Standing
|
Type
|
Air- cooled
|
After-sales Service Provided:
|
Spare parts, Video technical support, Online support
|
Number of Compressor
|
1
|
Refrigerant
|
R410A
|
Power Supply
|
220V-50HZ/380V-50HZ
|
Cooling Capacity
|
4-22KW
|
Airflow m3/h
|
1600-6500
|
Outdoor Unit
|
Separate Provided
|
Warranty
|
1 year
|
Application
|
Server Room, Computer Room, IT Equipment Room
|
1.1 | All equipment's provided under this specification shall be commercially in operation which is field proven for at least five years within three or more countries outside the manufacturer country. |
1.2 | AHU materials shall be avoided from any part of the equipment. |
1.3 | Equipment size and weight shall be the minimum possible. |
1.4 | Construction of all equipment and quality of components shall be in accordance with the best current standards of air conditioning for strength, reliability, durability, and safety. |
1.5 | Parts requiring dust proofing, such as relays and contactors shall be protected with dust proof covers. |
1.6 | Wiring in each equipment shall be systematically color-coded and neatly wired. |
1.7 | All air conditioning equipment shall operate on 220V± 10%, single phase and a frequency of 50Hz±5%. |
1.8 | The system should restart automatically, when power turn on, after mains power failure. |
1.9 | The units (evaporator and condenser) shall be separable suitable for the installation of the condensing units out-door and the cooling unit indoor. |